5m Power Mains Pc LCD TV Kettle Cable Lead 3 Pin IEC 13 Amp Fused

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

The dimensions and tolerances for connectors, appliance inlets, appliance outlets and plug connectors are given in standard sheets, which are dimensioned drawings showing the features required for safety and interchangeability. IEC 60320-2-3: Couplers with a degree of protection higher than IPX0 [7] specifies couplers with some degree of liquid ingress protection (IP). In its second edition published in 2018, the standard sheets were moved to IEC 60320-3. When buying partner items like this one, your contract of sale will be with our Range Plus Partner instead of The Range. A C8B inlet type is defined by the standard for use by dual-voltage appliances; it has three pins and can hold a C7 connector in either of two positions, allowing the user to select voltage by choosing the position the connector is inserted. [22] The C13/C14 connector and inlet combination are used in a wide variety of electronic equipment ranging from computer components like the power supply, monitors, printers and other peripherals to video game consoles, instrument amplifiers, professional audio equipment and virtually all professional video equipment. A power cord with a suitable power plug (for the locality where the appliance is being used) on one end and a C13 connector (connecting to the appliance) on the other is commonly called an IEC cord.

The units themselves should be internally fused in any case. The fuse fitted to a 13Amp plug is really there as a last resort. The Samson unit will have overload protection also (there's a circuit breaker on the front of the unit that will trip in the event of an overload fault in the same way that a fuse would blow). The C7 figure 8 power lead is a 2 pin power cable, when viewed end on it looks like a number 8. Often found on small electrical appliances like radios and CD players. C13 to C14 Power Extension CablesI'd just like to thank you for the DC lead which you made for me. I received it today, and it does the job exactly as envisaged - so I'm a happy customer. In European countries the C15/C16 coupler has replaced and made obsolete the formerly common types of national appliance coupler in many applications. url="http://cpc.farnell.com/pro-elec/pe00070/rewireable-iec-plug/dp/PL09635"]http://cpc.farnell.c...plug/dp/PL09635[/url] The C13 connector and C14 inlet are also commonly found on servers, routers, and switches. Power cord sets utilizing a C13 connector and an E interconnection plug are commonplace in data centers to provide power from a PDU (power distribution unit) to a server. These data-center power cables are now offered in many colors. Colored power cables are used to color-code installations. [25] C15/C16 coupler [ edit ] The C19 power cable is used in higher current applications such as power PDUs in data centres, it is an industrial type connector, larger than the C13 and C15. Schuko Euro Power Cables

The IBM Wheelwriter series of electronic typewriters are one common application. Three-wire cords with C13 connectors, which are easier to find, are sometimes used in place of the two-wire cords for replacement. In this case, the ground wire will not be connected. Sometimes referred to as a kettle power lead the C13 connector has 3 pins, often found on PCs and TVs. C15 Power Cables (Hot Condition) Similar connector to C5/C6, but with a key ridge instead of an earthing conductor, withdrawn from standard.

This item is sold and dispatched by a Range Plus Partner

A cable consisting of a C13 and an E interconnection connector is commonly mislabeled as an "extension cord", as although that is not the intended purpose, it can be used as such. They are also commonly mislabeled as C14 instead of E. UL certification E152635 covering YC-12 C13, YC-20 C15 and YP-32 C14 connectors. Note that the manufacturer's YC-20 label contains an error; the wire gauges (18, 16, 14) are repeated in the "current rating" column; the UL certification contains the correct values (10A, 13A, 15A). Retrieved 2014-09-24.

Ah right cool, without risk of sounding stupid, is it as easy as just taking the plug off and putting the kettle lead end on? what about the fuse that's inside a normal plug? You have 3 units that have "built-in" mains cords (i.e. the mains cables cannot be disconnected from the units) and you want to connect them to your power distributor/monitor ? Appliance inlet: "part of the appliance coupler integrated as a part of an appliance or incorporated as a separate part in the appliance or equipment or intended to be fixed to it".Remove the 13 Amp plugs and replace them with the above C14 plugs. The C14 plug has Live, Neutral and Earth clearly marked inside the plug. The screw terminals can be a bit fiddly but patience pays off. For use in very-high-temperature settings, such as some stage lighting instruments. Similar to C15/C16, but the top is narrowed to exclude the C15 cord connector. One arbitrarily chosen example of a 1500W PSU with a C14 input is the Enermax MAXREVO 1500 W 80+ Gold. It manages to fit within the 15A input current limit because of its 80 Plus gold efficiency. Very common on personal computers and peripherals. Commonly referred to as a "kettle cord" or "kettle lead", [17] [18] but kettles in countries using 120V require the C15/C16.